EndoTherm EndoCool Flipbook PDF

EndoTherm energy saving additive for cooling systems.


113 Views
32 Downloads
FLIP PDF 1.36MB

DOWNLOAD FLIP

REPORT DMCA

Powered by

ENDOCOOL INTRODUCTION CONTACT:

Rob Black

07538 358166 [email protected]

The

Effect

System fluid

Radiator external wall

Radiator external wall

Applications • EndoCool is dosed into the secondary circuit of a wet cooling system • Dosed into a system at a ratio of 1 litre per 100 litres of system volume • No need to drain down the system fluid • Installation requires a certified HVAC installer • EndoCool will work synergistically with or without glycol antifreeze to deliver power saving as well as ensuring good climatic control of the airspace

Sample Installation Results

Case Study – Comfort Cooling EMCOR UK: Thirlmere House Warrington IPMVP Analysis – Pre & Post EndoCool 1000 900

System fluid

Electricity Consumption (kWh)

800 700 600



50 litres of EndoCool installed

500



Office building with small server room

400



FCU for comfort cooling



Radiatortest external wall 3 week study

200



Data recorded every 30 seconds

100



22.16% saving compared to baseline



Trialled using IPMVP Protocols

300

Radiator external wall

0 0

1

2

3

CDD

4

5

6

7

Case Study – Data Centre EMCOR UK: Lingley Mere Data Centre Warrington IPMVP Analysis – Pre & Post EndoCool 27000



50 litres of EndoCool installed



Large Data Centre (process cooling only)



7 week test study

23000



Data recorded every 30 seconds

22000



4.63% saving compared to baseline

21000



£700 saved

20000



8 month ROI



Radiator external wall

Electricity Consumption (kWh)

26000

System fluid

25000 24000

19000

Radiator external wall

Trialled using IPMVP Protocols

18000 0

5

10

15

20

25

30

Outside Temp (oC)

Note: process cooling or systems on 24/7 do NOT cycle & EndoTherm/EndoCool will not improve cycling or reduce run times. Therefore these systems should save in the region of 5%.

Case Study – Comfort Cooling Blue: Park Place (Dubai) • 54 storey skyscraper in Dubai’s Central Business District comprising offices, hotel & residential units • The primary load of the building is comfort cooling & requires constant air conditioning • EndoCool installed into 3 chilled water loops totalling 55,000 litres which make up cooling system IPMVP Analysis – Pre & Post EndoCool

800,000

y = 972.21x + 130153 R² = 0.9706

Electricity Consumption (kWh)

700,000 600,000 500,000

Baseline

400,000

Post-EndoCool Linear (Baseline)

300,000

Linear (Post-EndoCool) 200,000 100,000 0

100

200

300

400

CDD

500

600

700

Rob Black EndoTherm & EndoCool Business Development Partner M: +44 (0)7538 358166 E: [email protected] W: www.endoenterprises.com Endo Enterprises (UK) Ltd Unit 231 Europa Boulevard Gemini Business Park Warrington Cheshire WA5 7TN