Data Loading...
Product Data Sheet HD-SD 3050 Flipbook PDF
Product Data Sheet HD-SD 3050
121 Views
53 Downloads
FLIP PDF 277.09KB
Product Data Sheet HD-SD 3050
HD SERIES Sprung Drive High-Speed Rubber Door
Features •
•
The HD-SD 3050 high-speed, chain drive, spring counterbalanced door is equipped with a high-performance helical gearhead operator to open the door at up to 48 inches per second. The HD-SD 3050 operator is controlled by a custom programmable PLC with a variable frequency drive (VFD) in a NEMA 4 enclosure for precision control and durability.
•
Counterbalanced by standard springs rated for 100,000 or 50,000 cycles, depending on the size of the door.
•
Upgrades for 200,000 cycles in higher traffic applications are available.
•
Available for doors up to 25 feet wide and 30 feet high OR 30 feet wide and 20 feet high
The typically harsh environments of heavy industrial applications are where these extremely reliable doors are most valuable where high opening speeds are necessary.
Technical Data
Remark
Application
Exterior or Interior Opening Closing
Speed
Opening 48 ips (1.2 m/s)
Roll-up Technology
Size Range
Guide Track Profile Roll Tube Diameter Window Size Required Headroom Drive Mechanism Counterbalance System Braking Cycleability / Maintenance Safety Features Resistance to Wind Load Fire Resistance Rating Warranty
“up to” maximum speed for this model depending on door size
Mechanical limit panel - 20” W x 24” H x 11” D (510 mm W x 610 mm H x 280 mm D)
Control Panel
Door Construction
Closing 32 ips (0.8 m/s)
Hollow-core steel roll tube with precision-welded axles Min. 6’-0” (1830 mm) up-to 30’-0” (9145 mm) wide Min. 6’-0” (1830 mm) up-to 30’-0” (9144 mm) high 5 1/2” x 9” (140 mm x 230 mm) / 9” x 9” (230 mm x 230 mm) 8 5/8” (219 mm) 16” x 16” (406 mm x 406 mm), 1/8” (3 mm) thick 32 1/2” (825 mm) / 37” (940 mm)
Concrete mount / steel mount (W x D) Hollow core Opening heights up to 17’ 0” (5185 mm) / over 17’ 0” x (5185 mm)
Chain drive operator 50K or 100K cycle counterbalance spring (depending on door size) Control box activated DC disc brake
Optional BMH brake rectifier for cold temperatures
100 cycles per day / Inspection every three months Integrated in-line light grid, manual chain hoist 20 pounds per square foot (1.0 kPa) windclass 5
ANSI / DASMA 108-2002
Non-rated, Non-conforming exit Curtain - Limited lifetime (10 years Europe) General mechanical/electrical - 2 years
5 year operator warranty with VFD controls 2 year operator warranty with relay logic controls
1-2
Product Data Sheet (Continued) HD-SD 3050
HD SERIES Sprung Drive High-Speed Rubber Door
Materials and Finishes Curtain Guides Mounting Angles Bottom Bar Endplates Truss Roll Tube Idler Barrel Weather Seals Electric Door Operator Control Box Hood and Motor Cover
Standard 1/4” (6 mm) Black SBR
Optional 1/4” (6 mm) Blue or Grey EPDM, Black Nitrile, Black MSHA
5” (127 mm) aluminum extrusion 10 gauge roll formed high strength galvanized steel with gussets Extruded aluminum weighted bottom bar with patented pivoting arms Zinc dichormate plated steel Fabricated steel construction, painted Galvanized steel Galvanized steel Self sealing rubber curtain/guides, EPDM loop seal on bottom bar, brush seal at lintel HG helical gear high efficiency chain drive operator
Optional high corrosion upgrade
Optional NEMA Type 4 or 4X Standard separate control panel with VFD and (IP66) separate control panel, contactors with relay PLC logic or PLC 18 gauge galvanized steel
Energy Analysis Visible Transmittance (Tvis) Solar Heat Gain Coefficient (SHGC) Thermal Resistance (R-value) Heat Transfer Coefficient (U-value) Acoustic Insulation
0.147 (h · ft² · °F)/Btu 6.781 Btu/(h · ft² · °F)
0.026 (m² · °K)/W 38.5 W/(m² · °K)
ASTM C518 – 10 ASTM C518 – 10
Sound transmission Class (STC) 28dB Outdoor-Indoor transmission class (OITC) 23 dB
ASTM E 90-09 / E 413-10 / E1332 - 10a
Manaras Pro FDGH 2-3 HP (1.5-2.25 kW) varies
NEMA Type 4 (4X Optional) IP66
230-600 VAC, 3 PH, 60 Hz
Voltage same as Supply power
LEED Credit (Potential)
Electrical Electric Door Operator (Motor) Operating Voltage (Motor) Control Box Standard Power Requirement (to Control Box)
2-3 HP (1.5-2.25 kW) variable frequency drive rated for operator voltage
NEMA Type 4 (4X Optional) IP66 CSA Listed (Canada/US)
208-600 VAC, 3 PH, 60 Hz
Full Load Amps
Varies 2.82 - 12.0 A
Operator
Disconnect
Fuse: 20 A, Class K
Service to control box supplied by others
TNR Industrial Doors | 200 Fairview Road, Unit 2 | Barrie, ON L4N 8X8 1-866-792-9968 | 705-792-9968 | TNRdoors.com 2-2 We reserve the right to change specifications without notice. © HTNR Industrial Doors Inc (Issue 02/2022) Print