Modbus Slave Communication

Record of Revisions Reference numbers are shown at the bottom left corner on the back cover of each manual. Printing Date July, 2006

Reference No. 1046NE0

Revised Contents First edition

Preface Thank you for selecting the MONITOUCH V7/V6 series. For correct set-up of the V7/V6 series, you are requested to read through this manual to understand more about the product. For more information about the V7/V6 series, refer to the following related manuals. Manual Name

Contents

Reference No.

Reference Manual (Operation)

The V-SFT operating procedure is described.

1043NE

Reference Manual (Function)

The functions and instructions of the V7/V6 series are explained.

1044NE

PLC Connection Manual

Connections with various PLCs and universal serial communications are explained.

2200NE

V7 Hardware Specifications

Notes on usage and hardware specifications for the V7 series are described.

2010NE

V706 Hardware Specifications

Notes on usage and hardware specifications for the V706 are described.

2012NE

V6 Hardware Specifications

Notes on usage and hardware specifications for the V6 series are described.

2006NE

Temperature Control Network

The temperature control network function is explained.

1033NE

Connection with AB Control Logix

The connection, communication parameters and tag setting for AB Control Logix are explained.

1041NE

M-CARD SFT Operation Manual

The operating procedure of the memory card editor is described.

1023NE

V-SFT Additional Specifications

Additional specifications for the Reference Manual are explained.

5044NE

For further details about PLCs (programmable logic controllers), see the manual attached to each PLC.

Notes: 1. This manual may not, in whole or in part, be printed or reproduced without the prior written consent of Hakko Electronics Co., Ltd. 2. The information in this manual is subject to change without prior notice. 3. Windows and Excel are registered trademarks of Microsoft Corporation in the United States and other countries. 4. All other company names or product names are trademarks or registered trademarks of their respective holders. 5. This manual is intended to give accurate information about MONITOUCH hardware. If you have any questions, please contact your local distributor.

Notes on Safe Usage of MONITOUCH In this manual, you will find various notes categorized under the following levels with the signal words “DANGER,” and “CAUTION.”

DANGER

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and could cause property damage.

Note that there is a possibility that the item listed with

CAUTION may have serious ramifications.

DANGER • Never use the input function of MONITOUCH for operations that may threaten human life or damage the system, such as switches used in case of emergency. Please design the system so that it can cope with malfunction of a touch switch. A malfunction of the touch switch will result in machine accident or damage. • Turn off the power supply when you set up the unit, connect new cables or perform maintenance or inspections. Otherwise, electrical shock or damage may occur. • Never touch any terminals while the power is on. Otherwise, electric shock may occur. • You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Without the terminal cover in place, electric shock may occur. • The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, do not ingest the leaked liquid crystal. If the liquid crystal spills on your skin or clothing, use soap and wash off thoroughly. • For MONITOUCH using a lithium battery, never disassemble, recharge, deform by pressure, short-circuit, nor reverse the polarity of the battery, or dispose of the battery in fire. Failure to follow these conditions will lead to explosion or fire. • For MONITOUCH using a lithium battery, never use a battery that is deformed, leaks, or shows any other signs of abnormality. Failure to follow these conditions will lead to explosion or fire.

CAUTION • Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found. Failure to do so may lead to fire, damage or malfunction. • For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or mobile installations, please consult your local distributor. • Operate (or store) MONITOUCH under the conditions indicated in this manual and related manuals. Failure to do so could cause fire, malfunction, physical damage or deterioration. • Understand the following environmental limits for use and storage of MONITOUCH. Otherwise, fire or damage to the unit may result. - Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding fluids or cutting oil can come into contact with the unit. - Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct sunlight. - Avoid locations where excessive dust, salt, and metallic particles are present. - Avoid installing the unit in a location where vibration or physical shock may be transmitted. • Equipment must be correctly mounted so that the main terminal of MONITOUCH cannot be touched inadvertently. Otherwise, an accident or electric shock may occur. • Tighten the fixtures of MONITOUCH with a torque in the specified range. Excessive tightening may distort the panel surface. Loose tightening may cause MONITOUCH to come off, malfunction or be short-circuited. • Check periodically that terminal screws on the power supply terminal block and fixtures are firmly tightened. Loosened screws may result in fire or malfunction. • Tighten terminal screws on the power supply terminal block equally to a torque of 0.5 N•m. Improper tightening of screws may result in fire, malfunction, or other trouble. • MONITOUCH has a glass screen. Do not drop or give physical shock to the unit. Otherwise, the screen may be damaged. • Connect the cables correctly to the terminals of MONITOUCH in accordance with the specified voltage and wattage. Over-voltage, over-wattage or incorrect cable connection could cause fire, malfunction or damage to the unit. • Be sure to establish a ground of MONITOUCH. The FG terminal must be used exclusively for the unit with the level of grounding resistance less than 100Ω. Otherwise, electric shock or fire may occur. • Prevent any conductive particles from entering into MONITOUCH. Failure to do so may lead to fire, damage or malfunction. • After wiring is finished, remove the paper used as a dust cover before starting to operate MONITOUCH. Operation with the cover attached may result in accident, fire, malfunction, or other trouble. • Do not attempt to repair MONITOUCH at your site. Ask Hakko or the designated contractor for repair. • Do not disassemble or modify MONITOUCH. Otherwise, it may cause a malfunction. • Hakko Electronics Co., Ltd. is not responsible for any damages resulting from repair, overhaul or modification of MONITOUCH that was performed by an unauthorized person. • Do not use a sharp-pointed tool when pressing a touch switch. Doing so may damage the screen. • Only experts are authorized to set up the unit, connect the cables or perform maintenance and inspections. • For MONITOUCH using a lithium battery, handle the battery with care. The combustible materials such as lithium or organic solvent contained in the battery may generate heat, explode, or catch fire, resulting in personal injury or fire. Read related manuals carefully and handle the lithium battery correctly as instructed. • When using a MONITOUCH that has an analog switch resolution with resistance film, do not press two or more points on the screen at the same time. If two or more positions are pressed at the same time, the switch located between the pressed positions will activate. • Take safety precautions during such operations as setting change during running, forced output, start, and stop. Any misoperation may cause unexpected machine motions, resulting in machine accident or damage. • In facilities where a failure of MONITOUCH could lead to accident threatening human life or other serious damage, be sure that the facilities are equipped with adequate safeguards. • At the time of disposal, MONITOUCH must be treated as industrial waste. • Before touching MONITOUCH, discharge static electricity from your body by touching grounded metal. Excessive static electricity may cause malfunction or other trouble.

[General Notes] • Never bundle control cables and input/output cables with high-voltage and large-current carrying cables such as power supply cables. Keep these cables at least 200 mm away from high-voltage and large-current carrying cables. Otherwise, malfunction may occur due to noise. • Plug connectors or sockets of MONITOUCH in their correct orientation. Otherwise, malfunctions may occur. • Do not use thinners for cleaning because they may discolor the MONITOUCH surface. Use an alcohol-based cleaner which is commercially available. • If a data receive error occurs when MONITOUCH and the counterpart (PLC, temperature controller, etc.) are started at the same time, read the manual for the counterpart unit and handle the error correctly. • Avoid discharging static electricity on the mounting panel of MONITOUCH. Static charges can damage the unit and cause malfunctions. Otherwise, malfunction may occur due to noise. • Avoid prolonged display of any fixed pattern. Due to the characteristics of the liquid crystal display, an afterimage may occur. If a prolonged display of a fixed pattern is expected, use the auto OFF function of the backlight.

Contents Preface Notes on Safe Usage of MONITOUCH 1.

Outline Modbus Protocol.................................................................................................................................. 1-1 Modbus Slave Communication............................................................................................................ 1-2

2.

Connection Applicable Devices .............................................................................................................................. 2-1 Communication Setting (For Slave)..................................................................................................... 2-1 Connection .......................................................................................................................................... 2-2

3.

Modbus Slave Communication Outline of Communication ................................................................................................................... 3-1 Slave Setting ....................................................................................................................................... 3-2 Master Setting ..................................................................................................................................... 3-6

4.

Use of MONITOUCH as Modbus Master Outline of Communication ................................................................................................................... 4-1 Slave Setting ....................................................................................................................................... 4-1 Master Setting ..................................................................................................................................... 4-1 Connection .......................................................................................................................................... 4-2 Connection with Multiple MONITOUCH as Slaves .............................................................................. 4-3

5.

Appendix System Memory ($s) ........................................................................................................................... 5-1 Error..................................................................................................................................................... 5-1

1. Outline

1.

1-1

1

Outline

Modbus Protocol • The Modbus protocol, developed by Modicon, is a communication protocol widely adopted for PLCs or other devices. • Under the Modbus protocol, a master and its slaves always exist. Communications will be established in a manner that the master sends out requests to the slaves and they send back responses. Master

Slave Request

Slave address

Slave address

Function code

Function code

Data

Response

Error check

Data Error check

• There are two modes in the Modbus protocol. They are ASCII and RTU. These two modes use different message formats. MONITOUCH performs Modbus slave communications in the Modbus RTU mode. • Broadcast from the master is not supported. • MONITOUCH is capable of communicating either as a master or a slave.

1-2

1. Outline

Modbus Slave Communication • Under the Modbus protocol, the master can read from and write to the PLCs or temperature controllers connected to MONITOUCH as slaves. This form of communication through the mediation of MONITOUCH will eliminate the need for complicated settings and will allow varied devices to communicate without restraint via simple connections. • Any device enabled to operate as a Modbus RTU master can become a master in Modbus slave communications. • In a case where the Modbus master reads from or writes to the PLC memory or the temperature control memory that is connected to a slave MONITOUCH, the PLC or temperature control memory gains access to the Modbus protocol memory addresses. To enable its accessing, setting the memory tables provided for MONITOUCH is required. (For more information, refer to “Memory Table” in page 3-2.)

Example 1) Connecting with a computer A computer acts as the Modbus master, and MONITOUCH acts as slave. In this example, the computer accesses memory specified in the Modbus-specific memory tables in MONITOUCH, and thereby data exchanges between the computer and the PLC connected to MONITOUCH are enabled.

disc

Modbus master RESET

Modbus RTU MJ1/MJ2

Modbus slave

MJ1/MJ2

SYSTEM

SYSTEM

F1

F1

F2

F2

F3

F3

F4

F4

F5

F5

F6

F6

F7

POWER

Modbus slave

F7

POWER

RS-232C/RS-422

RS-232C/RS-422

PROGRAMMER

1. Outline

1-3

1

Example 2) Connecting between MONITOUCH

Modbus RTU MJ1/MJ2

MJ1/MJ2

Modbus master

SYSTEM

SYSTEM

F1

F1

F2

F2

F3

F3

F4

F4

F5

F5

F6

F6

F7

Modbus slave

F7

POWER

POWER

RS-232C/RS-422

RS-232C/RS-422

PROGRAMMER

MONITOUCH acts as both the Modbus master and the Modbus slave. The master gains access to the slave on the temperature control network (Modbus Free). The master accesses the Modbus addresses of the slave, and thereby can receive data from the slave-side PLC. At the same time, the master-side PLC can send data to the slave-side.

Connection Outline The Modbus master can be connected to the modular jack (MJ1/MJ2) of MONITOUCH as a Modbus slave via RS-232C or RS-485. Via RS-232C

Via RS-485

disc

disc

RESET

RESET

A maximum of 31 sets of MONITOUCH are connectable.

RS-485

RS-232C MJ1/MJ2

MJ1/MJ2

MJ1/MJ2

SYSTEM F1

SYSTEM

SYSTEM

F1

F1

F2

F2

F3

F3

F4

F4

F5

F5

F2

F3

F4

F5

F6

F6

F6

F7

F7

F7

POWER

POWER

CN1 RS-232C/RS-422

POWER

CN1

CN1

RS-232C/RS-422

RS-232C/RS-422

PROGRAMMER

1-4

1. Outline

Please use this page freely.

2. Connection

2.

2-1

Connection

Applicable Devices

2

• Slave side V7/V6/V706 series * When one single V706 series is used, the MJ2 is dedicated to PLC connection. Typical users use the MJ1 for Modbus slave communication; however, with an option unit DU-01 installed, the MJ1 can also be used for Modbus slave communication. • Master side Devices which support to the Modbus RTU mode * The V7/V6/V706 series is usable also as the Modbus master. (For more information, refer to “Chapter 4 Use of MONITOUCH as Modbus Master”.)

Communication Setting (For Slave) Setting Procedure [System Setting] → [Modbus Slave Communication Setting] → [Communication Setting] → [Modbus slave communication setting] dialog 1. In the dialog, select [Modbus RTU] for [Comm. Protocol] (default setting: Not used). 2. The [Refer to modular] button becomes enabled. Click the button. The [Modbus Slave Table] dialog is displayed. Choose the MJ port to be used for Modbus slave communication and check [Modbus Slave]. Note: [Modbus Slave] and [V-Link] cannot be used simultaneously.

Setting Items The following setting items are provided for the MONITOUCH to act as a Modbus slave. Setting Items Comm. Protocol

Setting (underlined as a default) Modbus RTU (fixed)

Data Length

8-bit (fixed)

Signal Level

RS-232C, RS-485

Stop Bit

1-bit, 2-bit

Baud Rate

4800, 9600, 19200, 38400, 57600, 115200 bps *1

Local No.

1 to 31 (“0” not usable)

Send Delay (× msec) Parity Timeout (× msec)

0 to 255 None, Odd, Even 0 to 25 (2) *2

*1

A baud rate of 115,200 bps is not available for V606, V606i, V606e, and V609E.

*2

Timeout: The item [Timeout] for Modbus slave communication refers to the time for monitoring commands to be received from the master. When the specified timeout period has elapsed and no more data arrives, the data that has been received so far is recognized as one command.

2-2

2. Connection

Connection Cable Use Hakko Electronics’ V6-TMP (3 m) cable for connection with the Modbus master. The shielded cable (V6-TMP) is connected to the FG (frame ground) when the V7 series is used and to the SG (signal ground) when V706 is used. V6-TMP

* Notes on Use of V6-TMP There are six wires in the V6-TMP cable as shown on the right. The wires to be used are determined depending on the connecting method. For wires not in use, be sure to properly insulate with tape, etc.

(Pin No.) Black: 1 Green: 2 Brown: 4 Red: 5 Orange: 7 Yellow: 8

Via RS-232C (with one MONITOUCH) Modbus Master (a) V6-TMP

RS-232C MJ1/MJ2 SYSTEM F1

F2

F3

F4

F5

F6

F7

POWER

CN1

RS-232C/RS-422

Wiring example of above (a) Modular jack, 8-pin Signal Name

Pin No.

*1

*1

Master: Computer D-sub 9-pin (female) Signal Name

Pin No.

SD

8

RD

2

RD

7

SD

3

SG

5

SG

5

DR

6

RS

7

CS

8

V6-TMP is connected to the FG when the V7 series is used and to the SG when the V706 is used.

2. Connection

2-3

Via RS-485 (with a maximum of 31 MONITOUCHs) Modbus Master

RS-232C → RS485 conversion

(a) Terminal block

Terminal block

}*

}*

(b) V6-TMP

Terminal block

MJ2/1

}*

MJ2/1 SYSTEM

SYSTEM

F1

F1

F1

F2

F2

F2

F3

F3

F4

F4

F5

F5

F6

F6

F7

F7

F3

F4

F5

F6

F7

POWER

CN1

RS-485

MJ2/1

SYSTEM

POWER

}

2

POWER

CN1

CN1

RS-232C RS-422 PROGRAMMER

PLC

PLC

PLC

* 0.5-m-long cable recommended (1.0 m maximum)

Wiring example of above (a) and (b)

(a)

RS-485

Terminal

Terminal

Signal Name

Signal Name

Signal Name

FG

FG

FG

+

+

+







SG

SG

SG

V7 series Modular jack, 8-pin Signal Name (b)

Pin No.

*1

V7 series Modular jack, 8-pin Signal Name

Pin No.

*1

+

1

+

1



2



2

SG

5

SG

5

*1

V6-TMP is connected to the FG when the V7 series is used and to the SG when the V706 is used.

2-4

2. Connection

Please use this page freely.

3. Modbus Slave Communication

3.

3-1

Modbus Slave Communication

Outline of Communication • By means of Modbus slave communication, the Modbus master connected to MONITOUCH as a slave gains access to the device that is connected to MONITOUCH. • The addresses 400001 to 465536 of the holding register are available to Modbus slave communication. By allowing the PLC memory or the temperature controller memory (connected to MONITOUCH) to access the holding register, the master is enabled to monitor or write to the PLC or the temperature controller through MONITOUCH. Modbus master

Modbus slave (MONITOUCH)

SYSTEM

Modbus RTU

disc

F1

F2

F3

F4

F5

RESET

F6

PLC

F7

POWER

Holding register

When the master accesses address 432769 in MONITOUCH to read, it actually reads the value at D100 in the PLC. Likewise, when an instruction to change the value at 432775 is given to MOINITOUCH, the value at D106 in the PLC is changed.

PLC memory

432769

D100

432770

D101

432771

D102

432772

D103

432773

D104

432774

D105

432775

D106

(Memory table)

• Setting the holding register and the PLC memory in relation to each other can be made in the memory tables for MONITOUCH (page 3-2).

3

3-2

3. Modbus Slave Communication

Slave Setting Setting Procedure 1. Communication setting [System Setting] → [Modbus Slave Communication Setting] → [Communication Setting] → [Modbus slave communication setting] dialog 2. Memory table [System Setting] → [Modbus Slave Communication Setting] → [Memory Table] → [Modbus Slave Table] 3. Connection Establish a connection with the Modbus master through either MJ1 or MJ2. 4. Communication start Start accessing a memory table in MONITOUCH from the master.

Communication Setting For information, refer to page 2-1.

Memory Table Structure It is possible to create 256 memory tables in total. One single memory table includes 31 free areas. To these free areas, addresses of MONITOUCH and the device connected to MONITOUCH can be assigned. Each memory table is provided with the holding register, to which the master gains access. Modbus master

Modbus slave SYSTEM

Modbus RTU

disc

F1

F2

F3

F4

F5

RESET

F6

F7

POWER

Write

Table Table 400001 - 0000 H -No. n Table 1400001 - 0000 -No. H 416385 - H4000 Table No. 0 400001 0000 H 416385 - 4000 - H432769 - H8000 Internal memory 400001 - 0000 -- H8000 416385 - H4000 -- H8400 432769 - H433793 Internal memory 416385 4000 H 432769 - 8000 -- H8800 433793 - H8400 - H434817 Free area 432769 - 8000 -- H8800 433793 - H8400 - H434817 area 433793 - 8400 - HFree 434817 - H8800 -

434817 -

Read

Free area 8800 H 462465 - F400 H -

No. 255 0 0

1

0

1

0

0

1

0

1

1

0

1

2

0

1

2

1

2

2

462465 - F400 - H463489 - H F800 462465 - F400 -- H 463489 - H F800 464513 FC00 H-

29 29

30

29

30

31

31

Free area 462465 - F400 -- H 463489 - H F800 464513 FC00 H Free 463489 F800 H 464513 - FC00 H - area

29

30

30

31

Free area

31

464513 -

FC00 H -

:Areas common to all tables Holding register * Assignment to free area 31 is not performed directly in the memory tables. Desired memory addresses will be assigned to the area from the master. (Refer to page 3-10.)

3. Modbus Slave Communication

3-3

Specify the desired table number in the range of 0 to 255, to which the master gains access. (MONITOUCH internal memory address $s800 is used. For more information, refer to page 3-8.) The master will access the MONITOUCH-side device addresses assigned to the holding register in the specified table. Modbus master

Modbus slave SYSTEM

Modbus RTU

disc

F1

F2

F3

F4

PLC

F5

RESET

F6

F7

POWER

No. 255

417185 (= $s800) = 1 Table No. 1 is selected for accessing free areas.

The master accesses the address 434817 of the holding register to read.

The value at D2048 in the PLC memory (on the MONITOUCH side) can be monitored.

400001 -

0000 H -

No. n

0

400001 - - 0000 H -H - No. 1 416385 4000 0 Internal memory 400001 - - 0000 H -H -H No. 416385 432769 - 4000 8000 -

0 1

0 1 0 $u0 400001 - - 0000 H -H -H - Internal memory 0 1 0 $s0 416385 432769 - 4000 433793 - 8000 8400 H 1 416385 - - 4000 H -H -H - Free area 1 0 1 D0000 432769 8000 433793 8400 434817 - 8800 H 2 432769 - - 8000 0 1 2 D1024 H -H -H - Free area 433793 434817 - 8400 8800 433793 - - 8400 H -H 1 2 Free area 434817 D2048 8800 434817 - 8800 H 462465 - F400 H -

2

29

462465 - - F400 H -H 463489 F800 area 462465 - - F400 H -H -H Free 463489 464513 - F800 FC00 -

2930 293031M0000 -

462465 - - F400 H -H -H - Free area 463489 464513 - F800 FC00

293031 R0000 3031

463489 - - F800 H -H 464513 FC00 464513 -

FC00 H -

Free area

31

Memory Table Setting Click [System Setting] → [Modbus Slave Communication Setting] → [Memory Table]. The [Modbus Slave Table] dialog is displayed.

Free area 0

15

3

3-4

3. Modbus Slave Communication

Clicking the [Next] button displays the following free areas.

Free area 15 →

Free area 16 →

Free area 30 → Free area 31 →

Checking the box of any free area allows you to specify a top memory address as desired. When an address is specified, the consecutive 1024 words starting from the top memory address will automatically be assigned. * Setting in the dialog is enabled for free areas 0 - 30. The above dialog is not applied to internal memory ($s, $u) area 0 and area 1 that are already set, and free area 31 (PLC memory, temperature control memory, $L, etc.), to which addresses will be assigned from the master. To go to memory table No. 1 and after (up to 255), change the value for [No.] in the upper left corner of the dialog.

3. Modbus Slave Communication

3-5

Memory table list (1 table) Holding Register

Memory Table

Modbus Slave Side

400001 - 416384 (16384 words)

0000 H - 3FFF H

Internal memory area 0 $u0 - 16383

416385 - 417408 (1024 words)

4000 H - 43FF H

Internal memory area 1 $s0 - 1023

432769 - 433792 (1024 words)

8000 H - 83FF H

Free area 0 (PLC memory, temperature control memory, $L, etc.)

433793 - 434816 (1024 words)

8400 H - 87FF H

Free area 1 (PLC memory, temperature control memory, $L, etc.)

434817 - 435840 (1024 words)

8800 H - 8BFF H

Free area 2 (PLC memory, temperature control memory, $L, etc.)

435841 - 436864 (1024 words)

8C00 H - 8FFF H

Free area 3 (PLC memory, temperature control memory, $L, etc.)

436865 - 437888 (1024 words)

9000 H - 93FF H

Free area 4 (PLC memory, temperature control memory, $L, etc.)

437889 - 438912 (1024 words)

9400 H - 97FF H

Free area 5 (PLC memory, temperature control memory, $L, etc.)

438913 - 439936 (1024 words)

9800 H - 9BFF H

Free area 6 (PLC memory, temperature control memory, $L, etc.)

439937 - 440960 (1024 words)

9C00 H - 9FFF H

Free area 7 (PLC memory, temperature control memory, $L, etc.)

440961 - 441984 (1024 words)

A000 H - A3FF H

Free area 8 (PLC memory, temperature control memory, $L, etc.)

441985 - 443008 (1024 words)

A400 H - A7FF H

Free area 9 (PLC memory, temperature control memory, $L, etc.)

443009 - 444032 (1024 words)

A800 H - ABFF H

Free area 10 (PLC memory, temperature control memory, $L, etc.)

444033 - 445056 (1024 words)

AC00 H - AFFF H

Free area 11 (PLC memory, temperature control memory, $L, etc.)

445057 - 446080 (1024 words)

B000 H - B3FF H

Free area 12 (PLC memory, temperature control memory, $L, etc.)

446081 - 447104 (1024 words)

B400 H - B7FF H

Free area 13 (PLC memory, temperature control memory, $L, etc.)

447105 - 448128 (1024 words)

B800 H - BBFF H

Free area 14 (PLC memory, temperature control memory, $L, etc.)

448129 - 449152 (1024 words)

BC00 H - BFFF H

Free area 15 (PLC memory, temperature control memory, $L, etc.)

449153 - 450176 (1024 words)

C000 H - C3FF H

Free area 16 (PLC memory, temperature control memory, $L, etc.)

450177 - 451200 (1024 words)

C400 H - C7FF H

Free area 17 (PLC memory, temperature control memory, $L, etc.)

451201 - 452224 (1024 words)

C800 H - CBFF H

Free area 18 (PLC memory, temperature control memory, $L, etc.)

452225 - 453248 (1024 words)

CC00 H - CFFF H

Free area 19 (PLC memory, temperature control memory, $L, etc.)

453249 - 454272 (1024 words)

D000 H - D3FF H

Free area 20 (PLC memory, temperature control memory, $L, etc.)

454273 - 455296 (1024 words)

D400 H - D7FF H

Free area 21 (PLC memory, temperature control memory, $L, etc.)

455297 - 456320 (1024 words)

D800 H - DBFF H

Free area 22 (PLC memory, temperature control memory, $L, etc.)

456321 - 457344 (1024 words)

DC00 H - DFFF H

Free area 23 (PLC memory, temperature control memory, $L, etc.)

457345 - 458368 (1024 words)

E000 H - E3FF H

Free area 24 (PLC memory, temperature control memory, $L, etc.)

458369 - 459392 (1024 words)

E400 H - E7FF H

Free area 25 (PLC memory, temperature control memory, $L, etc.)

459393 - 460416 (1024 words)

E800 H - EBFF H

Free area 26 (PLC memory, temperature control memory, $L, etc.)

460417 - 461440 (1024 words)

EC00 H - EFFF H

Free area 27 (PLC memory, temperature control memory, $L, etc.)

461441 - 462464 (1024 words)

F000 H - F3FF H

Free area 28 (PLC memory, temperature control memory, $L, etc.)

462465 - 463488 (1024 words)

F400 H - F7FF H

Free area 29 (PLC memory, temperature control memory, $L, etc.)

463489 - 464512 (1024 words)

F800 H - FBFF H

Free area 30 (PLC memory, temperature control memory, $L, etc.)

464513 - 465536 (1024 words)

FC00 H - FFFF H

Free area 31 (PLC memory, temperature control memory, $L, etc.)

* When assigning PLC memory, temperature control memory, or $L to individual free areas, be sure to reserve 1024 words from the top memory address.

Connection For information, refer to page 2-2.

Communication Start For information, refer to page 3-8.

3

3-6

3. Modbus Slave Communication

Master Setting The tasks below are required for master settings. • Specifying a slave memory table number (Note that internal memory ($u, $s) and free area 31 are accessible, irrespective of the memory tables. When accessing these areas, you do not need to specify a table number.) • Reading the holding register of the slave • Writing to the holding register of the slave

Applicable Commands Description

Function No. (Code)

Read Holding Registers

03 (03 H)

Write Single Registers

06 (06 H)

Diagnostics

08 (08 H)

Write Multiple Registers

16 (10 H)

Applicable Memory Memory

Description

Holding Register (words) 400001 to 465536 *1 (0000 to FFFF H) *2

Read Holding Registers

03 (03 H)

Write Single Register

06 (06 H)

Write Multiple Registers

16 (10 H)

*1 *2

Function No. (Code)

Reference number Hexadecimal number

Modbus RTU Format Reading the holding register

Writing to the holding register

Slave Address

XX H*1

Slave Address

Function Code

03 H

Function Code

Starting Address No. of Registers Error Check

Hi

XX H

Lo

XX H

Hi

XX H

Lo

XX H

Hi

CRC (16 bits)

Lo

Starting Address Quantity of Registers *

*1 XX H 10 H*2 Hi

XX H

Lo

XX H

Hi

XX H

Lo

XX H

Byte Count * Register’s Value 1

Register’s Value n Error Check

XX H Hi

XX H

Lo

XX H

Hi

XX H

Lo

XX H

Hi

CRC (16 bits)

Lo

*1

Broadcast from the master (broadcasting commands to slaves by specifying port No. 00) is not supported.

*2

Function code 10 H is used for writing to multiple words of the holding register. For writing to one word of the holding register, function code 06 H is also usable. In the latter case, defining the number and the byte count is not necessary.

3. Modbus Slave Communication

3-7

Access Example Modbus slave communication is executable in a configuration as the following example. Modbus master

Modbus slave

SYSTEM

Modbus RTU

disc

F1

F2

F3

F4

F5

RESET

PLC

F6

F7

POWER

Memory table

Modbus slave In Modbus slave memory table No. 1, the values for 5 words starting from D2000 specified at free area 1 will be monitored by the master and then changed.

* Specifying a memory table number is not necessary when accessing the internal memory ($u, $s) or free area 31 that are independent of memory tables.

No. 255 400001 -

0000 H -

No. n

0

400001 - - 0000 H -H - No. 1 416385 4000 Internal memory 0 400001 0000 H 416385 4000 H -H No. 432769 - 8000 -

0 1

0 1 0 $u0 400001 - - 0000 H -H -H - Internal memory 0 1 0 $s0 416385 4000 432769 8000 433793 - 8400 H 1 416385 - - 4000 H -H -H - Free area 1 0 1 D0000 432769 433793 - 8000 434817 - 8400 2 8800 H 432769 - - 8000 H -H -H - Free area 0 1 2 D1024 433793 434817 - 8400 8800 433793 - - 8400 H -H 1 2 Free area 434817 D2048 8800 434817 - 8800 H 462465 - F400 H -

2

29

462465 - - F400 H -H 463489 F800 area 462465 F400 H 463489 F800 H -H Free 464513 - FC00 -

2930 293031M0000 -

462465 - - F400 H -H -H - Free area 463489 464513 - F800 FC00

293031 R0000 3031

463489 - - F800 H -H 464513 FC00 464513

Free area

FC00 H

31

1. Specifying a MONITOUCH-side memory table number (writing to the holding register) Specify the desired memory table number from the master first. Modbus master

Modbus slave

SYSTEM

Modbus RTU

disc

F1

F2

F3

F4

F5

RESET

F6

PLC

F7

POWER

Writing “1” to address $s800 in MONITOUCH

Writing “1” (= table No. 1) from the master to the MONITOUCH internal memory address $s800 allows accessing to free areas in table No. 1. * The value at $s800 cannot be changed directly on MONITOUCH. It is changeable only through communication from the master. Address $s800 stores the default value “−1.” Be sure to specify the desired table number from the master. The RTU format is defined as follows: Slave address

01 H

← MONITOUCH station number (01 or later)

Function code

06 H

← Writing to one word of the holding register

Hi

43 H

← Address of the target

Lo

20 H

Hi

00 H

Address Register’s value Error check

Lo

01 H

Hi

CRC (16 bits)

Lo

(4320 H = 4000 H + 320 H (= 800)) ← Data to be written

3

3-8

3. Modbus Slave Communication

2. Reading the holding register (MONITOUCH side) Read 5 words starting from address D2000 at free area 1 in table No. 1 from the master. Modbus master

Modbus slave

SYSTEM

Modbus RTU

disc

F1

F2

F3

F4

F5

RESET

PLC

F6

F7

POWER

Reading the values at PLC addresses D2000 to D2004

According to the definition of free area 1 (page 3-8), the accessing target is D2000 = holding register 434769 = hexadecimal No. 87D0 H. The RTU format is defined as follows: Slave address

01 H

← MONITOUCH station number (01 or later)

Function code

03 H

← Reading the holding register

Hi

87 H

← Top address D2000

Lo

D0 H

Hi

00 H

Lo

05 H

Hi

CRC (16 bits)

Starting address No. of registers Error check

Lo

(87D0 H = 34768, 400001+ 34768 = 434769) ← Word count

3. Writing to the holding register (slave) Write values to addresses as specified below: D2000 = 100 (= 64 H) D2001 = 5000 (= 1388 H) D2002 = 1234 (= 4D2 H) D2003 = 789 (= 315 H) D2004 = 200 (= C8 H) Modbus master

Modbus slave

SYSTEM

Modbus RTU

disc

F1

F2

F3

F4

F5

RESET

F6

F7

POWER

Writing values to 5 words of the PLC memory D2000 = 100 (= 64 H) D2001 = 5000 (= 1388 H) D2002 = 1234 (= 4D2 H) D2003 = 789 (= 315 H) D2004 = 200 (= C8 H)

PLC

3. Modbus Slave Communication

3-9

The RTU format is defined as follows: Slave address

01 H

← MONITOUCH station number (01 or later)

Function code

10 H

← Writing to multiple words of the holding register

Hi

87 H

← Top address D2000 = 434769

Lo

D0 H

Hi

00 H

Starting address Quantity of registers

Lo

05 H

Byte count Regester’s value Regester’s value Regester’s value Regester’s value Regester’s value Error check

(434769 − 400001 = 34768, 34768 = 87D0 H) ← Word count (5 words)

Hi

0A H

← Byte count (10 bytes)

00 H

← Data to be written

Lo

64 H

Hi

13 H

Lo

88 H

Hi

04 H

Lo

D2 H

Hi

03 H

(100) (5000) (1234) (789)

Lo

15 H

Hi

00 H

Lo

C8 H

Hi

CRC (16 bits)

Lo

3

(200)

Memory Assignment to Free Area 31 MONITOUCH free area 31 can be defined from the master. The area will be helpful when the access area from the master should be changed depending on conditions. Modbus master

Modbus slave SYSTEM

Modbus RTU

disc

F1

F2

F3

F4

F5

RESET

PLC

F6

F7

POWER

Memory table

No. 255 400001 -

0000 H -

No. n

400001 - - 0000 H -H - No. 1 416385 4000 Internal memory 0 400001 0000 H 416385 4000 H -H No. 432769 - 8000 Internal memory 400001 - - 0000 H -H -H 416385 432769 - 4000 433793 - 8000 8400 H 416385 - - 4000 H -H -H - Free area 432769 433793 - 8000 434817 - 8400 8800 H 432769 8000 H -H -H - Free area 433793 8400 434817 - 8800 Free area 433793 - - 8400 H -H 434817 8800

0 0 1 0 1 0 $u0 0 1 0 $s0 1 1 0 1 D0000 2 0 1 2 1 2

D1024 D2048 -

434817 - 8800 H 462465 - F400 H -

2

462465 - - F400 H -H 463489 F800 area 462465 F400 H 463489 F800 H -H Free 464513 - FC00 Free area 462465 F400 H 463489 F800 H 464513 - FC00 H -

2930 293031M0000 293031 R0000 -

463489 - - F800 H -H 464513 FC00 464513 -

FC00 H -

Free area

29

3031 31

Memory assigned to this area is changeable from the master.

Irrespective of the memory table number currently being accessed, free area 31 is always assigned to holding register addresses 464513 to 465536 (FC00 H to FFFF H). Slave internal memory (system memory) addresses $s801 to 805 are used to define memory for free area 31.

3-10

3. Modbus Slave Communication

System Memory ($s) The settings of the system memory depend on the type of memory to be defined. • MONITOUCH internal memory ($u, $s, $L/$LD (0 - 65535)) PLC memory (0 - 65535) Temperature control/PLC2Way memory (0 - 65535) Description

System Memory

15

$s801

(MSB)

8

7

(LSB)

Model

$s802

0

Memory type

Top memory number (address)

$s803

Extension code

00 H

$s804

00 H

Station number

$s805

00 H

• MONITOUCH internal memory ($L/$LD (65536 or later)) PLC memory (65536 or later) Temperature control/PLC2Way memory (65536 or later) Description

System Memory

15

$s801

(MSB) Model

8

7

(LSB)

0

Memory type

$s802

Top memory number (address) lower-order

$s803

Top memory number (address) higher-order

$s804

Extension code

00 H

$s805

00 H

Station number

- Model, memory type (HEX) Model

Memory Type

00

01

$u $s Internal memory

$L $LD $T

PLC memory Temperature control memory

00

0 - 65535 65536 -

80

0 - 65535

00

65536 -

80

0 - 1023

00

0 - 65535

01

65536 -

81

0 - 65535

03

65536 -

83

02 03 04 The memory type depends on the PLC or memory used. Refer to the PLC Connection Manual and set the type of the memory. The memory type depends on the memory used. Refer to the Temperature Control Network Manual and set the type number of the memory.

- Extension code (HEX) Set an extension code when you specify a SPU memory slot number for a Mitsubishi PLC, etc. Ex.: Mitsubishi: Slot No. 0: 00 H Mitsubishi: Slot No. 1: 01 H Yokogawa: CPU No. 1: 00 H Yokogawa: CPU No. 2: 01 H JTEKT: PRG No. 1: 00 H JTEKT: PRG No. 2: 01 H - Port No. (HEX) 1:1 or multi-link: Not used Multi-drop: Set the PLC station number. Temperature controller: Set the temperature controller station number.

3. Modbus Slave Communication

3-11

• Memory card System Memory

Description 15

(MSB)

$s801

8

7

02 H

(LSB)

0

File number

$s802

Word address in the record

$s803

Record number

$s804

00 H

$s805

00 H

3

Memory Assignment Example In this example, memory addresses D100 and after of the Mitsubishi QnH-series PLC will be assigned to MONITOUCH free area 31 and then 50 words starting from D100 will be read. Modbus master

Modbus slave

SYSTEM

Modbus RTU

disc

F1

Mitsubishi QnH

F2

F3

F4

F5

RESET

PLC

F6

F7

POWER

Memory table

400001 -

0000 H -

Internal memory

0

$u0 -

416385 -

4000 H -

Internal memory

1

$s0 -

432769 -

8000 H -

Free area

0

433793 -

8400 H -

Free area

1

463489 -

F800 H -

Free area

30

464513 -

FC00 H -

Free area

31

D0100 -

Memory can be assigned to this area from the master.

1. Define memory for free area 31 using MONITOUCH system memory addresses $s801 to 805. The RTU format is defined as follows: Slave address

01 H

← MONITOUCH station number (01 or later)

Function code

10 H

← Writing to multiple words of the holding register

Hi

43 H

← Top address

Lo

21 H

Hi

00 H

Lo

05 H

Starting address Quantity of registers

Register’s value Register’s value Register’s value Register’s value Error check

← Word count (5 words)

0A H

← Byte count (10 bytes)

Hi

01 H

← $s801

Lo

00 H

Hi

00 H

Byte count Register’s value

$s801 = 4321 H 4321 H = 4000 H + 321 H (=801)

Lo

64 H

Hi

00 H

Lo

00 H

Hi

00 H

Lo

00 H

Hi

00 H

Lo

00 H

Hi

CRC (16 bits)

Lo

Data to be written Model and memory type 0100 H ← $s802 Data to be written Top memory address 0064 H (= 100) ← $s803 Data to be written Extension code 0000 H ← $s804 Data to be written Station number 0000 H ← $s805 Data to be written 0000 H

3-12

3. Modbus Slave Communication

2. Read 50 words starting from the assigned D100. The RTU format is defined as follows: Slave address

01 H

← MONITOUCH station number (01 or later)

Function code

03 H

← Reading the holding register

Hi

FC H

← Top address Top address at free area 31

Lo

00 H

Hi

00 H

Starting address Quantity of registers Error check

Lo

32 H

Hi

CRC (16 bits)

Lo

FC00 H ← Word count 50 (32 H)

Notes • Memory assignment to free area 31 is allowed when MONITOUCH is in the state of RUN. When MONITOUCH is brought to the state of STOP, the assigned memory will be cleared. When you wish to use free area 31, be sure to assign memory at each start of the master-MONITOUCH communication. • Definition at $s800 to 805 cannot be changed directly on MONITOUCH. It is changeable only through communication from the master. • When setting a timeout period for the master associated with Modbus slave communication, the processing time (cycle time) required on MONITOUCH side should be taken into account. Ex.)When a processing time (cycle time) required between MONITOUCH and the PLC is approximately 150 ms: Modbus master

Modbus slave SYSTEM F1

disc

F2

F3

F4

F5

RESET

F6

F7

POWER

Timeout: (150 ms) + α

150 ms

The timeout period required on the master side is 150 ms or longer. For the additional time “+α” a processing time between the master and MONITOUCH should be considered. This processing time is determined by the amount of data to be accessed at one time. If the amount of data increases, the timeout period should also be increased appropriately.

4. Use of MONITOUCH as Modbus Master

4.

4-1

Use of MONITOUCH as Modbus Master

Outline of Communication It is possible to establish a connection between a MONITOUCH as a master and another MONITOUCH as a slave. This form of connection will greatly help read from/write to the PLCs connected to individual MONITOUCH.

4

Modbus RTU MJ1/MJ2

Modbus master

MJ1/MJ2

SYSTEM

SYSTEM

F1

F1

F2

F2

F3

F3

F4

F4

F5

F5

F6

F6

F7

POWER

Modbus slave

F7

POWER

RS-232C/RS-422

RS-232C/RS-422

PROGRAMMER

MONITOUCH acting as the Modbus master employs the temperature control network. For the execution of Modbus communication, MONITOUCH as a slave will be recognized as a Modbus Free device on the temperature control network.

Slave Setting Slave setting is the same as for a normal case (computer-MONITOUCH connection). For more information, refer to “Slave Setting” on page 3-2.

Master Setting MONITOUCH as the master will treat a slave MONITOUCH as a Modbus Free device on the temperature control network when communicating with it. * If the master MONITOUCH is already connected to any temperature controller or inverter, which is not Modbus Free, the Modbus slave function by means of the temperature control network is not available.

• [System Setting] → [Temp. CTRL/PLC2Way Setting] → [Temp. CTRL/PLC2Way Comm. Setting] Model:

Modbus Free

Communication parameter:

The same as that for the slave

Format setting:

Reading the holding register [62 words]

(Function code [03 H])

Writing to the holding register [62 words]

(Function code [10 H])

4-2

4. Use of MONITOUCH as Modbus Master

• Creating screens Setting the [Memory Input Temp. Mem. Modbus Free] dialog is necessary to allow the master to gain access to slaves. In the dialog, select [Temp. Mem.] under [Type]. In the case of Modbus Free, select [4] in the dialog for the holding register. Modbus master

Modbus slave Temperature control network SYSTEM

400001 1234 (=$u0) 432869 500 (=D100)

F1

F2

SYSTEM

Modbus RTU

F1

$u0

1234

F3

F2

F3

F4

F4

D100

F5

500

F6

F5

PLC

F6

F7

F7

POWER

POWER

Memory table

No. 255 400001 -

A reference number is determined from the hexadecimal number in the memory table, and then the reference number is specified as a holding register address.

No. n

0000 H -

400001 - - 0000 H -H - No. 1 416385 4000 Internal memory 0 400001 0000 H 416385 4000 H -H No. 432769 - 8000 Internal memory 400001 - - 0000 H -H -H 416385 432769 - 4000 433793 - 8000 8400 H 416385 - - 4000 H -H -H - Free area 432769 433793 - 8000 434817 - 8400 8800 H 432769 8000 H -H -H - Free area 433793 8400 434817 - 8800 Free area 433793 - - 8400 H -H 434817 8800

0 0 1 0 1 0 $u0 0 1 0 $s0 1 1 0 1 D0000 2 0 1 2 1 2

D1024 D2048 -

434817 - 8800 H 462465 - F400 H -

2

462465 - - F400 H -H 463489 F800 area 462465 F400 H 463489 F800 H -H Free 464513 - FC00 Free area 462465 F400 H 463489 F800 H 464513 - FC00 H -

2930 293031M0000 293031 R0000 -

Free area

463489 - - F800 H -H 464513 FC00 464513 -

FC00 H -

29

3031 31

As same as a normal Modbus slave communication (computer-MONITOUCH), specify a memory table number at slave address $s800 first for Modbus slave communication between MONITOUCHs. Once done, access to free areas is obtained. For the procedure used in setting the holding register for the master MONITOUCH, refer to the Temperature Control Network manual.

Connection Use the modular jacks MJ1/MJ2 for both master and slave. • RS-232C connection Pin arrangement on Pin arrangement MONITOUCH on the cable

Master MJ2/MJ1

Slave MJ2/MJ1

12345678 87654321

RD

7

RD

7

SD

8

SD

8

SG

5

SG

5

• RS-485 connection Master MJ2/MJ1

Slave MJ2/MJ1

+SD/RD

1

+SD/RD

1

-SD/RD

2

-SD/RD

2

5

SG

5

SG

4. Use of MONITOUCH as Modbus Master

4-3

Connection with Multiple MONITOUCH as Slaves Be sure to make the time for [Send Delay Time] on the master side longer than the time for [Timeout] on the slave side. If the master sends a command to slave No. 2 (“A” in the figure), slave No. 2 will return a response to the master and slave No. 1 (“a” in the figure). Normally, slave No. 1 does not recognize the response as a command to slave No. 1, and thereby does not process the response. After the receipt of the response from slave No. 2, however, slave No. 1 may receive a new command from the master (“B” in the figure) though a timeout has not occurred yet. In an incident like this, slave No. 1 will not accept the new command, regarding it just as another response from slave No. 2. SYSTEM F1

Master

F2

F3

F4

F5

F6

: Command to slave No. 2

F7

POWER

MJ2/1

(B)

: Response from slave No. 2

(A)

: Command to slave No. 1

(t)

(a) MJ2/1

MJ2/1 SYSTEM

SYSTEM

F1

F1

F2

(1)

F2

(2)

F3

F4

F5

F4

F6

F7

POWER

F3

F5

F6

F7

POWER

CN1

CN1

PROGRAMMER

PLC

PLC

To avoid the problem noted above, make the time for [Send Delay Time] (“t” in the figure) on the master side longer than the time for [Timeout] on the slave side so that a command will not be transmitted before a timeout occurs.

4

4-4

4. Use of MONITOUCH as Modbus Master

Please use this page freely.

5. Appendix

5.

5-1

Appendix

System Memory ($s) Address

Description

800

Modbus slave communication Reference table number

Memory Type

801

Modbus slave communication Memory setting for free area 31

802

Modbus slave communication Memory setting for free area 31

803

Modbus slave communication Memory setting for free area 31

804

Modbus slave communication Memory setting for free area 31

805

Modbus slave communication Memory setting for free area 31

←V

Error

5

Check

Data has some error Error: 180 ( : )

V7

V6

Error No.

Description

Remedy

180

The Modbus slave communication program is not found.

Transfer the screen data again.

181

The slave communication program is stored in the V series though [Modbus Slave] is not set for [Modular Jack] for the screen data.

Set [Modbus Slave] in the [Modular Jack] setting.

182

The [Modular Jack] setting for the screen data includes both [Modbus Slave] and [V-Link] settings.

[Modbus Slave] and [V-Link] are not usable simultaneously.

5-2

5. Appendix

Please use this page freely.

Hakko Electronics Co., Ltd.

1046NE0

Sales

890-1, Kamikashiwano-machi, Hakusan-shi, Ishikawa, 924-0035 Japan TEL +81-76-274-2144 FAX +81-76-274-5208

Tokyo Office

TEL +81-3-5767-6160

FAX +81-3-5767-6170

Osaka Office

TEL +81-6-6385-8234

FAX +81-6-6385-7851

Nagoya Office

TEL +81-52-789-0096

FAX +81-52-789-0098

Hiroshima Office TEL +81-82-568-0905

FAX +81-82-568-0922

60700000