Specifications and Features for E7C Drive Configured  The E7C Configured package provides an E7 drive in a NEMA 1 or NEMA 12 enclosure,  with space for several commonly used options, such as reactors, RFI filters, circuit  breakers, etc.  The E7 Drive is a variable torque AC drive, designed specifically for HVAC applications  in building automation. A new benchmark for size, cost, performance, benefits, and  quality, the E7 includes numerous built­in features such as network communications,  H/O/A, PI control, and energy­savings functions.  The E7 has embedded communications for the popular building automation protocols,  Johnson Controls Metasys N2 and Siemens APOGEE FLN, as well as Modbus. An  optional LonWorks interface card is also available.  E7 Performance Features · 

·  ·  · 

·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  · 

E7 Design Features

VT Ratings:  1/2­150 HP, 208 VAC  1/2­150 HP, 230/240 VAC  1/2­ 250 HP, 480 VAC Overload capacity: 110% for 60 sec  (150% peak) Starting torque: 100% at 3 Hz DC injection braking: at start or stop,  adjustable, current limited (anti­  windmilling) Motor preheat function Adjustable accel/decel: 0.1 to 6000  sec. Controlled speed range: 40:1 Critical frequency rejection: 3  selectable, adjustable bands Torque limiting: 30­180% Energy $aving control Torque boost: full range, auto Power loss ride­thru: 2 sec Inertia ride­thru Auto restart after power loss or  resettable fault, selectable, programmable Feedback signal loss detection Serial communications loss detection "Up/Down" floating point control  capability Stationary motor auto­tuning 

·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  · 

32­bit microprocessor logic Flash upgradeable firmware Non­volatile memory, program  retention Surface­mount devices Displacement power factor: 0.98 Output frequency: 0.1 to 120 Hz Frequency resolution: 0.06 Hz Frequency regulation: 0.1% Control Terminal Board: Quick  disconnect, removable Carrier frequency: selectable to 15  kHz 3%DC bus reactor: 30­150 HP, 208  VAC; 30­150 HP, 240 VAC; 40­500 HP, 480 VAC; optional on  lower ratings Keypad Operator: Hand/Off/Auto,  built­in copy feature, 7 languages LCD display: 5 lines, 16 characters  each 24 VDC control logic Transmitter/Option power supply Output contacts: One form C and  two programmable form A Input/output terminal status Input terminals: 5 programmable  multifunction input terminals Fault input: Programmable

Customizable monitor display Sleep function Run permissive input Ramp­to­stop or coast­to­stop  selection ·  Runtime changes in control and  display ·  Project­specific parameter  reinitialization  ·  ·  ·  · 

E7 Protective Features ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  · 

·  ·  ·  · 

·  ·  · 

Diagnostic fault indication in  selected language Timer function: Elapsed time, Delay  on start, Delay on stop RS­422/485 port: Embedded  Metasys N2, APOGEE FLN, and  Modbus Volts/hertz ratio: Preset and  programmable V/Hz patterns Multi­speed settings: 5 available Remote speed command: 0­10 VDC  or 4­20 mA, direct or reverse­acting Setpoint (PI) control with inverse or  square root input, differential control via two feedback capability Feedback signal: low pass filter Speed command: bias and gain Analog outputs: Programmable, two,  0­10 VDC Meter Functions: Volt, amp,  kilowatt, elapsed run time, speed  command Output Current Transformers, qty 3 NEMA 1 or NEMA 12 enclosure UL, cUL listed; CE marked; IEC 146 MTBF: exceeds 28 years 

·  Current limited stall prevention Heat sink over­temperature, speed  ·  fold­back Cooling fan operating hours recorded ·  ·  Bi­directional start into rotating  ·  motor at synchronized speed DC bus charge indicator ·  Current limiting DC bus fuse Optically­Isolated controls Short circuit protection: Phase­phase  ·  and phase­neutral ·  Ground fault protection ·  Short circuit withstand rating: 65K  ·  RMS, 100K RMS with bus reactor Electronic motor overload: UL Current and torque limit Fault display: last 10 faults E7 Service Conditions Fault circuit: OC, OV, OT Over torque and under torque  ·  Ambient Temperature:  protection ­10°C to 40°C(40°F to 104°F)  Program security code NEMA 1,  "Hunting" prevention logic ­10°C to 45°C(40°F to 113°F)  Reverse prohibit selectability protected chassis ·  Humidity: 95% RH, non­condensing ·  Altitude: 3300 ft; higher by derate ·  Input voltage: +10%/­15% ·  Input frequency: 50/60 Hz ± 5% ·  3­phase, 3­wire, phase sequence  insensitive 

E7 Configured Options

·  ·  ·  ·  ·  ·  ·  ·  ·  ·  ·  · 

Circuit breaker / Motor circuit  protector RFI/EMI filter Input fuses Input reactor Output reactor Engraved nameplates Speed potentiometer Pressure/electrical transducer Analog outputs: 2 programmable, 4­  20 mA 200 VA Control Transformer (fused) Communication Interface:  LonWorks DriveWizard upload/download and  monitoring/graphing software