X20DO8322

X20DO8322 1 General information The module is equipped with 8 outputs for 1-wire connections and designed for source output wiring. • • • •

8 digital outputs Source connection 1-wire connections Integrated output protection

2 Order data Model number X20DO8322

X20BM11 X20BM15

X20TB12

Short description Digital outputs X20 digital output module, 8 outputs, 24 VDC, 0.5 A, source, 1wire connections Required accessories Bus modules X20 bus module, 24 VDC keyed, internal I/O supply continuous X20 bus module, with node number switch, 24 VDC keyed, internal I/O supply continuous Terminal blocks X20 terminal block, 12-pin, 24 VDC keyed

Figure

Table 1: X20DO8322 - Order data

Data sheet V3.16

1

X20DO8322

3 Technical data Model number Short description I/O module General information B&R ID code Status indicators Diagnostics Module run/error Outputs Power consumption Bus Internal I/O Additional power dissipation caused by actuators (resistive) [W] 1) Certifications CE KC EAC UL HazLoc

ATEX DNV GL

LR KR Digital outputs Variant Nominal voltage Switching voltage Nominal output current Total nominal current Connection type Output circuit Output protection Diagnostic status Leakage current when switched off RDS(on) Peak short-circuit current Switch-on in the event of overload shutdown or short-circuit shutdown Switching delay 0→1 1→0 Switching frequency Resistive load Inductive load Braking voltage when switching off inductive loads Isolation voltage between channel and bus Electrical properties Electrical isolation Operating conditions Mounting orientation Horizontal Vertical Installation elevation above sea level 0 to 2000 m >2000 m Degree of protection per EN 60529

X20DO8322 8 digital outputs 24 VDC for 1-wire connections 0xA4AC I/O function per channel, operating state, module status Yes, using status LED and software Yes, using status LED and software (output error status) 0.26 W 0.8 W +0.42

Yes Yes Yes cULus E115267 Industrial control equipment cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X Temperature: B (0 - 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) ENV1 Yes FET positive switching 24 VDC 24 VDC -15 % / +20 % 0.5 A 4A 1-wire connections Source Thermal cutoff if overcurrent or short circuit occurs (see value "Peak short circuit current") Internal inverse diode for switching inductive loads (see section "Switching inductive loads") Output monitoring with 10 ms delay 5 µA 210 mΩ